22
Repair and Maintenance
Repair and Maintenance
Please cut off the electricity before repair and maintenance.
1. Check The Heat Conductor Level Periodically Or Before Starting Up.
(1) Please dismount the exhaust cap on the insulating tank.
(2) Take out the level meter; observe the liquid level mark on it.
(3) Please contact with the local distributor or the Atlantis Solar Air conditioner after sale
service center in time if the liquid is insufficient. Don’t open the machine by yourself.
2. Rinse the Air Filter
1) Dismount the filter
(1) Please open upwards the fore plate of the indoor unit.
(2) Extract downwards the two air filter screens.
2) Rinse the air filter screen
(1) Clean the filter screen by a dust collector.
(2) Wash the filter screens with clean warm water below 40℃.
3) Reinstall the filter screens after airing.
4) Close the inlet grilles of the indoor unit.
﹡Please rinse the filter screen every 15 days.